24-7 Services 1-800-632-9060

Motor Testing

Final Testing and Quality Assurance

Final testing to determine the quality of repair is essential for any customer.  Motor Technology has the ability to test run motors at full voltage up to and including 4160 VAC.  During the test run procedure, technicians are monitoring every aspect of the equipments operation.  This data is then incorporated into special reporting forms that are then emailed to the engineering staff at the customer location.  This detailed report is an excellent tool to document equipment repair history. 

 Test Equipment

  • Phoenix CL60 Computer Core Loss Tester
  • Phoenix AC Hypot
  • Surge Tester
  • Bar-to Bar armature tester
  • 1000 KVA Phoenix Computerized Test Center
  • 400 KVA Test Center
  • 900 HP @ 3600 RPM Dynamometer
  • 100 HP @ 3600 RPM Dynamometer

  • Dyna-Bal 7' swing 20,000 lbs
  • Dyna-Bal 6' swing 10,000 lbs

Other

  • Optalign Laser Alignment System
  • (2) CSI 2120 Data Collectors
  • Flir IR Viewer
  • ALL Pro Motor Tester 

Motor Circuit Analyzer

Fault Detection at the earliest stage.  Can find wiring faults that are turn-to-turn, phase-to-phase, open phase, or contaminated windings. 

Baker Analyzer AWA IV

  • Ramped HiPot
  • Surge Waveform
  • PI/DA test
  • DC HiPot
  • Resistance Test
  • Surge test